IO-Link station

IO-Link station report: commissioning data, wiring and bill of materials

StationIO-Link station
Date2026-10-11
DocumentStation report, rev. 1
Masters1
Sensors1
Ports used1 of 4

Open this station in the studio: iolinki.com/studio

3D layout

No 3D view captured.

Notes for the installer

No open points. Every sensor is inside its datasheet and wired to a master port.

1Wiring

2Cables

FromToDeviceRoute, mOrder lengthCheck
master1 X1L1LR20504.610 m≤ 20 m

Route is the laid path in the 3D model; order length adds 20 % slack and rounds up to a stock length.

3Ports and process data

PortDeviceVendor / device IDCycle timeProcess dataInput layoutData storage
master1 X1
IO-Link
LR2050
L1 · ifm electronic
310 / 479
type compatible
2.3 ms
min 2.3 ms · COM2
2 B in
0 B out
16 / 0 bit
Level bit 2-15, x1 mm
OUT2 bit 1
OUT1 bit 0
Backup + restore
master1 X2Deactivated, no device wired
master1 X3Deactivated, no device wired
master1 X4Deactivated, no device wired

Validation is set to type compatible (vendor ID and device ID must match). Use identical only when the device serial number is read at commissioning. Bit offsets count from the least significant bit of the input process data.

4Power budget

MasterSensors drawMaster suppliesPer portResult
master1 SIG200-0A0512200 (1089796)0 mAlimit not filed
No filed current: LR2050
within limits

5Parameter writes

PortParameterValueISDU index.subRawHexTypeStatus
master1 X1
L1
Probe length L1000 mm1600.0100003 E8IntegerTok
master1 X1
L1
Set point SP800 mm583.080003 20IntegerTok
master1 X1
L1
Reset point rP780 mm584.078003 0CIntegerTok
master1 X1
L1
Probe typerod 1602.0101UIntegerTok

Raw = round((value - offset) / gradient). Write with the master's ISDU function block or import the commissioning file. Values for inductive sensors are already converted to the steel-equivalent switching distance.

6Bill of materials

QtyKindVendorPartVendor / device ID
1masterSICKSIG200-0A0512200 (1089796)
1sensorifm electronicLR2050310 / 479
1probeifm electronicE43207 rod probe 1000 mm
1cableM12 A-coded 3/4-pole cable, 10 m

7Installer checklist

Commissioned byDate